Reichert Tonopen AVIA features the proven accuracy of the clinically trusted Tonopen XL, yet with ergonomics, four times the battery life, and larger LCD sreens. The renowned reliability of Reichert applanation tonometers allows you to take IOP measurements with confidence, anywhere, anytime and in any position. One of the best new features of the Tonopen AVIA is that it
requires no daily calibration.The Reichert Tono-Pen AVIA applanation tonometer is an easy to use hand held ophthalmic instrument, providing IOP readings that correlate strongly with the Goldmann Tonometer. The lightweight, ergonomic design, and advanced electronics of the new Tonopen AVIA allow operators to take fast accurate IOP measurements with minimal training. Reichert Tono Pen AVIA is powered by a
battery pack which is good for over 2,500 measurements. Tonopen AVIA, like the Tonopen XL, uses sanitized OCU-FILM Tip Covers to minimize the risk of cross-contamination. Please see new and improved
Ocu-Film+ Tono-Tip Covers 23-0651
now available.
Tonopen AVIA is highly portable and is designed to eliminate operator error. It starts with the push of a button. The Reichert Tonopen AVIA measures in any position, so it is ideal for patients in beds or wheel chairs. IOP measurement information is displayed on two large LCD screens. Your patients will appreciate the quick gentile measurement process.
The ergonomic design of the Reichert Tonopen AVIA tonometer enhances its versatility. The two LCD screens are positioned on either side of the instrument so that both left and right handed operators can easily see the measurement information. Grip zones help stabilize the Tonopen in virtually all hand sizes. Tonopen AVIA is extremely comfortable to hold, making it especially easy to transport and use on any patient, anywhere.
The Reichert TONO-PEN AVIA is intellignet, utilizing micro strain gauge technology and 1.0mm transducer tip. Advanced mircoprocessor technology provides objective IOP measuremens which are less influenced by operator-bias than Goldmann tonometry. The average of ten independent readings, combined with statistical confidence index ensure that the Tonopen AVIA will provide accurate, reliable and repeatable results. The measurement range of the new Reichert Tonopen AVIA is 5-55 mmHg, and dimensions are 6-1/4 inches by 3/4 inch by 1-3/4 inches.
The Reichert 23-0650 TONOPEN AVIA is supplied with Carrying Case, Instructional Manual & DVD, one box of 200 individually packaged Tonotip Covers, and one TONO-PEN AVIA POWERCEL Battery Pack.